ParameterWhy it mattersWhat we need from you
Compressor capacity
Free air delivery. This is the starting point for the volume calculation; roughly three to four times the capacity in liters is a common baseline.
m³/min or l/min
Consumption profile
Continuous or intermittent? If there are sudden, high peaks, volume is selected based on the peak, not average consumption.
Continuous / peaking
Operating and design pressure
Based on line pressure and the safety valve setting. On an 8-bar line, an 11-bar design is typical.
bar
Layout and location
Vertical or horizontal, indoor or outdoor? Outdoor installation needs corrosion protection and freeze prevention.
Vertical / horizontal + location
Body finish and interior coating
Painted steel is standard; galvanized or stainless is used in food and pharmaceutical lines. The surface the air contacts is decisive.
Painted / galvanized / stainless
Condensate drain type
A manual valve is cheap but easily forgotten. An automatic level-controlled drain is far safer in operation.
Manual / automatic
Fittings list
Safety valve, pressure gauge, ball valve and drain. Safety valve capacity is selected based on the compressor.
Valve capacity + fittings
Installation clearance and doorway size
The tank's mounting location, service clearance and entry doorway width. A tank that doesn't fit is a common problem.
Layout + doorway size